S 5004

Fig. A (right-hand installation) / fig. B (left-hand installation)
The thermostat sensor (5) must be fitted to the front of
the heater (room side). The thermostat sensor (5) and
capillary pipe (6) must not touch the heat exchanger or the
heater panelling or be kinked under any circumstances.
Left-side installation only
Carefully remove the thermostat sensor (5) at the snap-in clips
and place it on the opposite side (mirror-inverted) until it snaps
into position.
– Place heater in the floor cut-out.
– Clip thermostat sensor (5) with heat screen onto screws.
5
6
Figure 8
– Secure the appliance with 5 screws (3) 5.5 x 25 to the pre-
pared points in the corners and secure in the middle at the
front. Reinforce the floor structure at the screw-in points
using battens, for example.
– Remove control rod (7) from the support (60), insert through
the bush of the support from underneath and engage in the
safety pilot valve (8).
3
Figure 9

Auto ignitor removal / installation

Removal
– Before installing the exhaust duct, pull the auto ignitor (9)
out of the support.
Installation
– Install the auto ignitor (9) after fitting the exhaust duct.
– Before installing the auto ignitor, check that the plug con-
nections (11 + 12) are seated correctly.
– Insert the auto ignitor into the lugs (10) as far as it will go.
9
Figure 10

Roof cowl

S 3004 only
Cut an opening with a diameter of 60 mm + 1 mm. The dis-
tance between the centre of the opening and the side walls
must be at least 55 mm.
S 5004 only
Cut an opening with a diameter of 70 mm + 1 mm. The dis-
tance between the centre of the opening and the side walls
must be at least 60 mm.
7
If the roof has a double layer, line cavity with suitable heat-re-
60
sistant material (30) to stiffen roof so that it is not deformed
when the screws are tightened and remains watertight.
Insert cowl through roof from above and tighten from inside
with screwing ring (31). Secure screwing ring with screw (32).
S 3004
8
30
32
Figure 11
The pipe is sealed by the provided rubber seal – no additional
sealing required.
13
10
11
12
S 5004
30
31
32
31
21