S 5004
– Place the installation box outer part and inner part together
and secure them with 7 screws (3.5 x 9.5) – right-handed
installation (R) and left-handed installation (L).
– Secure the fan(s) (20) to the installation box with 3 screws
(3.5 x 19) for each. If no fan is installed the screws must
be screwed in anyway to prevent the installation box from
rattling.
– Place support (60) onto base (1a) in the installation box and
snap into place.
Internal control panel
– Push the control panel cable(s) (23 – silicon) for the fan
through the recess in the support and clip into the provid-
ed cable guide.
External control panel
– The control panel cable(s) (no picture) must not touch the
heater, the fan or the warm air duct. Secure the cable(s)
properly.
– Secure the installation box in the installation cut-out with
6 screws (3 x 12), each angled towards the outside. If this
is not possible, the installation box can be secured at the
side to the front of the installation cut-out with 4 screws.
– Secure the support (60) with 4 screws (3.5 x 16).
– Slide on the panel (61) from the front until it snaps into
position.
1a
2
3 x
23
60
1a
7
61
Figure 6
20
20
1
2 x
3 x
2 x
R
4 x
L
20
23
4 x
60
Installing the heater
S 3004
Fig. A (right-hand installation) / fig. B (left-hand installation)
The thermostat sensor (5) must be fitted to the front of
the heater (room side). The thermostat sensor (5) and
capillary pipe (6) must not touch the heat exchanger or the
heater panelling or be kinked under any circumstances.
Left-side installation only
Carefully remove the thermostat sensor (5) at the snap-in clips
and place it on the opposite side (mirror-inverted) until it snaps
into position.
– Place heater in the floor cut-out.
– Secure the appliance with 5 screws (3) 5.5 x 25 to the pre-
pared points in the corners and secure in the middle at the
front. Reinforce the floor structure at the screw-in points
using battens, for example.
– Remove the control rod (7) from the support (60), insert it
through the bush of the support from underneath and en-
gage it in the safety pilot valve (8).
3 x
5
Figure 7
1a
7
60
8
6
3