Poolex SPAWER ICESPA 7 Manuel D'installation Et D'utilisation page 63

Publicité

4.9
Setting
When the heat pump is off, press for 3 seconds.
The parameter code appears and the value is displayed after 3 seconds.
Use the arrows
and
To change a parameter:
1.
Display the parameter to be changed, then press
The parameter value starts flashing.
2.
Use the arrows
3.
Press
to confirm the input value.
Press
to return to the main interface.
List of user parameters
Code
Designation
Power-down memory mode
C1
Refrigeration inlet and outlet water
C3
temperature compensation settings
Heater relay function selection
C4
Ambient temperature judgment
C5
value for starting heater
Water temperature difference
C6
judgment value for restarting
heater
Water temperature difference
C7
judgment value for restarting
heater in manual mode
Circulation pump relay function
C8
selection
Water temperature interval for
C9
temperature checks
Water temperature difference for
C10
restart in heating mode
Water temperature difference when
C11
stopped in heating mode
Water temperature difference for
C12
restart in cooling mode
Water temperature difference when
C13
stopped in cooling mode
Dry contact function selection
C14
4. USE
OF CONTROL PANEL
to navigate between the different parameters.
and
to change its value.
and
to access the settings interface.
.
Range of values
1:On ; 0:Off
-4°C~0°C
0: Disabled
1: Automatic
2: Manual
-25°C~20°C
°C
°C
1
~5
°C
°C
1
~5
0: Disabled
1: Automatic
2: Manual
30~90min
°C
°C
0
~10
°C
°C
0
~10
°C
°C
0
~10
°C
°C
0
~10
0: Disabled
1: DOMOSWITCH
mode
Default value
1 / on
°C
0
0: Disabled
°C
5
°C
5
°C
2
0: Disabled
60min
°C
2
°C
2
°C
2
°C
2
1 / on
EN | 63