3. INSTALLATION
3.2
Installation diagram
The filter located upstream of the heat pump must be regularly cleared so that the water in the
system is clean, thus avoiding the operational problems associated with dirt or clogging in the filter.
* If the relay is installed outdoor, please install it with the wire outlet side facing down.
3.3
Hydraulic connection
Step 1
Screw the connectors for heat pump
3.4
Electrical connection
Pump's power plug integrates a 10mA differential
circuit breaker.
Regularly test the correct operation. In the event
of successive triggering or doubts contact the
after-sales service.
Before plugging in your heat pump, please
ensure the electrical socket is well protected,
properly grounded and protected from rain as
well as water projections.
Press the RESET button to start the heat pump.
The power indicator lights up in red: the heat
pump is on.
58 | EN
Step 2
Connect the water inlet and outlet
Power indicator
*
Test
Reset