Télécharger Imprimer la page

Wacker Neuson DPU 6555He Manuel De L'opérateur page 50

Publicité

Maintenance
5.7.2
T01007GB.fm
Changing the oil:
1. Remove extension plates if necessary.
2. Open filler bore (40).
Warning
Danger through overturning.
If the machine overturns, it can cause severe injury such as
crushing. Only use suitable and tested hoisting gear and lifting
tackle of sufficient lifting capacity.
Place the machine in a stable position.
3. Tilt vibration plate and keep it tilted until the oil has run out.
4. Place vibration plate in horizontal position.
Note
Avoid spilling oil. Remove any spilled oil immediately.
5. Pour in oil (see Technical Data) through the filler bore (40).
6. Close filler bore (40). (torque setting = 100 Nm)
7. Mount extension plates if necessary.
Do not pour in too much oil!