Télécharger Imprimer la page

Wacker Neuson DPU 6555He Manuel De L'opérateur page 47

Publicité

5.5
Battery
5.5.1
Note: Only replace defective batteries with original Wacker batteries.
Standard batteries are not suitable for the high vibration loads.
T01007GB.fm
Check acid level:
1. Remove battery cover.
2. Check acid level, if necessary top up with distilled water.
3. Secure battery cover.
Make sure the positive battery terminal cover is correctly in place
before proceeding to install the battery cover. Check to see that the
gas venting hose does not have any kinks!
Protect hands end eyes against the acid!
4. When changing the battery:
* Removal:
First disconnect negativ, then positive terminal of
battery.
* Assembly:
battery.
When using starting sprays etc., see chapter operation.
First connect positive, then negative terminal of
47