Télécharger Imprimer la page

Wacker Neuson DPU 6555He Manuel De L'opérateur page 40

Publicité

Maintenance
5.
Maintenance
5.1
Maintenance schedule
Component
Drive engine
Machine cpl.
Air filter
Drive engine
Centre pole height
setting, transport lock
Fuel tank
V-belt
Protective frame
Central lifting point
Tow-bar head
Exciter
Drive engine
Battery
Fuel filter
Air filter
Fuel injector
Injector valve
T01007GB.fm
Warning*
Danger of poisoning by exhaust fumes!
Exhaust fumes contain toxic carbon monoxide that can lead to
unconsciousness or death.
Always switch off the engine during maintenance work!
First oil change and filter.
Run a visual check to see that everything is
complete and undamaged.
Check area around combustion air intake and also
air filter service indicator.
Check oil level, if nec. top up oil.
Regrease.
Check water separator.
Check V-belt, if. nec. replace.
Check attachment screws for tight fit.
Check oil level, top up if necessary.
Oil change.
Oil change, change oil filter.
Keep cooling fins free of dirt, clean dry.
Retighten all accessible screw connections.
Check acid level, if nec. top up with distilled water.
Change filter.
Replace filter insert.
Clean, adjust if necessary, repair or replace.
Clean, adjust or replace if necessary.
Maintenance work
40
Maintenance interval
approx. 8 hours after
initial start-up
daily
weekly
monthly
every 250 h, or latest
every 6 months
every 250 h
every 500 h
every 1500 h
every 3000 h

Publicité

loading