Connect the switching power supply (20) to a suitable socket outlet. Once the charging station is
powered, one of the signal indicators (18) lights up blue (Fig. 25).
Signal indicator (18)
Lights up blue or red
Flashing blue and red
Flashing blue or red
NOTE: After connecting the boundary wire (19) to the wire terminals (15/16)
on the charging station (12), conduct a test run of the machine to ensure that it
correctly detects the boundary signal. Make any necessary adjustments to the
wire or connections if needed to ensure proper functionality.
EN Functions & Settings
Intended use
The 300 m
robotic lawnmower MCI1007RBM/TTI1008RBM is designated with a rated voltage of 20 V.
2
The machine is intended for mowing grass automatically only in lawns and grassed areas within gardens
and open spaces. It is not intended for mowing unusually high, dry, or wet grass, such as pasture grass, or
for shredding leaves.
•
Do not transport people, children or animals on the machine.
•
Do not use the machine to level out uneven patches.
•
Do not use the machine on unstable, slippery, icy, stony, rough, marshy ground or over puddles that do
not allow the consistency of the ground to be assessed;
•
Do not use the blades on surfaces other than grass.
For safety reasons it is essential to read the entire instruction handbook before first operation and to observe
all the instructions therein. This machine is intended for private domestic use only, not for any commercial
trade use. It must not be used for any purposes other than those described.
WARNING! The machine may be used by an experienced operator* having read
and understood the safety requirements provided within this instruction manual
using appropriate personal protective equipment (PPE)!
* A trained operator is a person who has the competence and knowledge in the use and hazards associated
with using a pressure washer as well as the precautions to be taken to limit these hazards.
5059340856001_MNL_EN_V07.indd 25
5059340856001_MNL_EN_V07.indd 25
18
Fig. 25
Description
Normal
Machine is charging
Poor or broken boundary wire connection
25
08/01/2024 12:40:06 pm
08/01/2024 12:40:06 pm