3 WIRING THE ACCESSORIES
For your safety, these operations must be carried out with the power supply switched off.
You are advised to perform auto-programming of the gate travel before connecting the accessories
(photoelectric cells, flashing light, etc.)
3.1 Photoelectric cells
It is not possible to connect a second set of photoelectric cells on this motorisation.
TX
1 2
▶ Installation
After wiring the photoelectric cells:
• switch the motor on again,
• start a gate opening or closing procedure.
The photoelectric cells are recognised by the control electronics once this movement is
complete.
▶ Operation with photoelectric cells
If the cells are blocked when closing the gate, the gate will stop and reopen. If the gate is open
and the cells are blocked, the gate will not close.
▶ In the event of photoelectric cell disconnection
After disconnection of the photoelectric cells, switch the motor on again then perform the procedure
"Deactivating automatic closing"on page 24.
18
EN - FREEVIA installation and operating guide - SOMFY
RX
1 2 3 5
TX
1 2
1 2
or
RX
1 2