3 Installation
Compare model number and type with that specified on hy-
draulic schematic. The valve can be mounted in any position,
fixed or movable. The venting screw has to point upwards
(only for D638/9).
Mounting
surface:
(< 0.01 mm (0.00004 in) over 100 mm (3.94 in)) and finish
(R
< 0.8 µm). Care must be taken to ensure that contamina-
a
tion does not enter the hydraulic system, all work areas must
be clean of surface or air-borne contamination.
Mounting: Socket head screws (grade 10.9) according to
EN ISO 4762, torque diagonally alternating.
Pattern to
Series
ISO 4401
D636/8
03-03-0-05
D637/9-P
05-05-0-05
D637/9-R
05-05-0-05
4 Operating Pressure
Maximum operating pressure p
5 Electrical Connection
Electrical safety: The protective conductor connection is con-
nected to the electronics housing or valve body. The insulation
materials employed are designed for use in the safety extra-
low voltage range. The field bus circuit connections are only
functionally galvanically isolated from the other connected cir-
cuits.
To comply with safety regulations requires isolation from the
mains according to EN 61558-1 and EN 61558-2-6 and limiting
all voltages according to EN 60204-1. We recommend using
SELV/PELV power supplies.
Rated signal: See nameplate.
External fuse per valve: 2.0 A time lag (for D636/8) and
3.15 A time lag (for D637/9)
Valve phasing: A positive signal (D–E) for 6+PE connector or
(4–5) for 11+PE connector causes valve opening PA.
Connector wiring: See wiring schematic tag attached to elec-
tronics housing, or refer to the catalog or the installation draw-
ing.
Connection: Signal lines shielded, shielding connected at
both ends and additionally connected to reference potential
(0 V) at the control side (to improve EMC). Connect the protec-
tive conductor.
Observe technical note TN 353.
6 Hydraulic System Start Up
Pay attention to the pressure setting, the venting instructions
and the alarm messages!
7 Venting (only for D638/9)
WARNING
Hydraulic fluid squirting out
Hydraulic fluid squirting out under high pressure or
parts falling off can cause serious personal injuries,
burns and fires.
 Only vent the valve and the actuator at a low sys-
tem pressure of max. 10 bar (145 psi).
 Carefully open the venting screw by approx. one
revolution.
8 Null Adjustment
The null adjustment of the valve and further parameterizations
can be done via the field bus.
Page 2/2
Check
for
flatness
Socket
Torque
head screw
Pcs.
[Nm]
M5 x 55
4
6.8
M6 x 40
4
M6 x 60
4
: See nameplate.
P
9 Service
Replacing O rings: The mounting surface O rings may be re-
placed by the customer. Pay attention to cleanliness of the
valve and of the surroundings.
Transportation: Before transporting a valve the valve ports
have to be sealed with a clean shipping plate or adhesive tape.
Package the valve carefully to prevent damage during trans-
portation.
Repairs: Repairs may only be carried out by us or by our au-
thorized service centers.
Repaired valves or replacement valves are delivered like
new valves with factory settings. Therefore, the valves have
to be checked for correct configuration and changed parame-
terization before re-initiation. If necessary, the user has to re-
store the machine manufacturer's original configuration and
parameterization.
11
10 Disposal
11
It is essential to comply with the relevant national waste dis-
posal regulations and environmental protection provisions
when disposing of valves, spare parts or accessories, packag-
ing that is no longer needed, hydraulic fluid or auxiliary materi-
als and substances used for cleaning!
Mounting and Installation Notes D636/7/8/9 (B97072-636-001; Version E, 07/13)