4.7
Function
The submersible probe measures the hydrostatic pressure at the tank bottom
and converts it into a voltage signal. The voltage signal is transmitted to the
control unit.
The control unit calculates the content of the tank and displays the content in
litres, m³, % or liquid level in mm.
A calculation of remaining range can be carried out on the basis of the con-
sumption determination.
When the alarm switching point (for example, minimum or maximum level) is
reached, the red LED lights solid and the audible alarm sounds.
In conjunction with an additional submersible probe (ZT), level differences in
two tanks (for example, battery tanks) can be detected.
The optional floating probe (ZS) can be used for backflow alarms (for exam-
ple, in rain water harvesting systems).
Voltage-free changeover contact
The voltage-free changeover contacts switch the alarm for additional equip-
ment (for example, horn, warning light with rotating reflector).
4.8
Approvals, conformities, certifications
The product complies with:
•
EMC Directive (2014/30/EU)
•
Low Voltage Directive (2014/35/EU)
•
RoHS Directive (2011/65/EU)
Product description
TankControl 10
EN E N
13