5 - TECHNICAL DATA
For the technical data, please consult the data plate applied to the product (Fig.1).
6 - INCONVENIENCES AND POSSIBLE REMEDIES
MALFUNCTION
The appliance doesn't work.
The appliance doesn't switch on.
The appliance only works for a small amount
of time.
The appliance doesn't cool efficiently.
The appliance is noisy and vibrates ex-
cessively.
Water leaks from the conditioner during
transport.
The display shows 'E1'.
The display shows 'E2'.
Do not try to repair the appliance by yourself.
If the problem has not been solved, please contact your local retailer or the closest assistance service.
Supply detailed information about the malfunction and the equipment version.
EN - 18
CAUSE
No power.
The plug has not been inserted.
LED S9 on
---------------------------------------------------------
In COOLING mode: environment tempera-
ture is lower than the set temperature
---------------------------------------------------------
In HEATING mode: ambient temperature is
higher than the set one.
The temperature set is too close to ambient
temperature.
---------------------------------------------------------
Suction of outside air is obstructed.
The air filters are clogged by dust, fluff or
animal hair.
---------------------------------------------------------
The drain pipe not connected or it is clogged.
---------------------------------------------------------
The appliance has a low level of refrigerant.
---------------------------------------------------------
Temperature setting is too high.
---------------------------------------------------------
The windows or doors of the room are open.
---------------------------------------------------------
The room area is too large.
---------------------------------------------------------
Heat sources are present inside the room.
The appliance bearing surface is not levelled.
---------------------------------------------------------
The air filters are clogged by dust, fluff or
animal hair.
The conditioner has been tilted or laid flat.
Ambient temperature sensor faulty.
Pipe temperature probe faulty.
WHAT DO I DO?
Wait.
Insert the plug in the power socket.
The water collection tray is full. Switch off the
appliance, unload water from the collection
tray and then restart the appliance.
---------------------------------------------------------
Reset temperature.
---------------------------------------------------------
Reset temperature.
Lower the temperature set.
---------------------------------------------------------
Remove the obstructions.
Call the Service Centre.
Switch off the appliance and clean the filters
following the instructions.
---------------------------------------------------------
Switch off the appliance, disconnect the
pipe, remove the possible obstruction and
reconnect the drain pipe.
---------------------------------------------------------
Contact an assistance centre to have the appli-
ance inspected and the refrigerant topped-up.
---------------------------------------------------------
Reduce the set temperature.
---------------------------------------------------------
Make sure all the windows and the doors
are closed.
---------------------------------------------------------
Check the cooling area again.
---------------------------------------------------------
Remove the heat sources if possible.
Place the appliance on a flat and levelled surface.
---------------------------------------------------------
Switch the appliance off and clean the filters
following the instructions.
Empty water before moving the appliance.
Call the Service Centre.
Call the Service Centre.

Publicité

loading