Troubleshooting
BNCLJT05 / 2021463
4.2
Errors
If your machine encounters an error while it runs a formula, the
formula halts, the operator signal sounds, and an error code dia-
log box
(Figure 24, page
See the next section for a list of all the error codes and the possi-
ble causes/solutions.
4.2.1
MilTouch™ Error Messages
The following are error messages the controller can issue, possible causes, and solutions. Opera-
tion stops and cannot be resumed until the cause of the error is corrected. This can require a main-
tenance or chemical technician.
Door Opened — The controller cannot confirm that the door to the washer-extractor is closed.
If this occurs while a formula is in progress, the controller turns off all outputs, cancels the wash
formula, and returns to the Home display.
The Door Opened: Close the door.
Electrical failure: If the door is not open, electrical troubleshooting is required.
Too Long to Fill — The water in the machine did not reach the specified level within the con-
figured Fill Error Time. The controller closes all water valves and turns off all chemical injec-
tions. The Fill Error timer resets after you correct the error.
Fill Time Configured too Short: Do a check of the configured fill time in your machine's
configuration decisions. It may be necessary to increase the fill time.
Low Water Pressure: Do a check of the water pressure and volume to the machine.
Water Valve Malfunctioned: Use the electrical schematic manual to do a check of the
water valves and the circuits that control the valves.
Too Long to Drain — The water in the machine did not drop to the specified level within the
allotted drain time. The controller issues an error but the drain remains open. If a slow drain
caused the error, the error clears and the formula resumes when the transducer senses that the
water level has dropped to the desired level.
Drain Blocked: The drain pipe from the machine to the sewer may be blocked. Check the
drain pipe and remove any obstruction.
Transducer Tube Blocked: The tube from the shell to the pressure transducer
page
29) may be blocked. Check the tube and remove lint or other obstructions.
28
28) appears on the Run display.
BNCLJT05
0000213864
F.2
BNCLUT03.C28 0000204090 C.2 F.2 E.5 9/11/20, 3:45 PM Released
Figure 24. Sample Error
Code Dialog Box
BNCLUT03.R01 0000188209 C.2 E.3 F.2 11/9/21, 3:56 PM Released
11/9/21, 4:01 PM
Released
(Figure 25,
Pellerin Milnor Corporation