13.0 Troubleshooting JWDS‐2244OSC‐M Drum Sander
Symptom
Drum motor won't start
when switch is activated.
Drum motor will not start:
fuses blow or circuit
breakers trip.
Drum motor overheats.
Drum motor stalls,
resulting in blown fuses or
tripped circuit.
Loud, repetitive noise or
vibration coming from
machine.
Conveyor motor stalls.
Conveyor belt does not
move.
Conveyor rollers run
intermittently.
Conveyor belt slips on drive
roller.
Abrasive strip comes off
drum.
Abrasive strip is loose.
Abrasive loads up
prematurely.
Line or groove in stock.
Possible Cause
No incoming current.
Low voltage.
Open circuit in motor or loose connection. Inspect all lead connections on motor for loose
Switch malfunction.
Short circuit in line cord or plug.
Short circuit in motor or loose
connections.
Incorrect fuse or circuit breaker in power
line.
Air circulation through motor restricted.
Motor overloaded (SandSmart
functioning properly).
Short circuit in motor or loose
connections.
Low voltage.
Incorrect fuse or circuit breaker in power
line.
Fasteners loose.
Motor fan is hitting cover.
Machine not level.
Excessive depth of cut.
Shaft coupler is loose or unattached.
Shaft coupling is loose.
Improper conveyor belt tension.
Excessive depth of cut and/or feed rate.
Slack in abrasive strip on drum.
Abrasive improperly wrapped.
Strip caught on inside edge of slot, or on
inboard side of drum.
Strip not cut properly.
Excessive depth of cut.
Excessive feed rate.
Inadequate dust collection.
Inadequate abrasive.
Inconsistent feed rate.
Correction *
Check connections at plug or circuit panel.
Check power line for proper voltage.
or open connections.
Replace switch.
Inspect cord or plug for damaged insulation and
shorted wires.
Inspect all connections on motor for loose or
shorted terminals or worn insulation.
Install correct fuse or circuit breaker.
Clean motor fan with compressed air to restore
normal air circulation.
TM
not
Have controls inspected and repaired.
Inspect connections on motor for loose or
shorted terminals or worn insulation.
Correct low voltage conditions.
Install correct fuse or circuit breaker.
Inspect fasteners and tighten where needed.
Tighten fan or shim fan cover.
Place sander on level floor; shim if needed.
Reduce depth of cut; use coarser grit; reduce
feed rate.
Adjust shaft coupler.
Align the shaft flats of the gear motor and the
drive roller and tighten the shaft‐coupling
setscrews.
Adjust belt tension.
Reduce depth of cut and/or feed rate.
Remove slack in strip.
Read the section on installing abrasives, and
rewrap.
Re‐adjust the strip end in the slot and/or trim
the abrasive edge.
Re‐cut and re‐install the abrasive strip.
Reduce depth of cut.
Reduce feed rate.
Increase airflow at dust port.
Use an open‐coat abrasive.
Do not stop or change the feed rate while
feeding stock.
20