xFUME™ ADVANCED HP 230V – CSA
The device may be used only for the purpose and in the manner described in this documentation.
Any other use is considered non-intended. Unauthorized conversion work or modifications to
increase performance are not permissible.
► Only operate the unit with original ABICOR BINZEL spare parts.
► Do not exceed the maximum load data given in the documents. Excess loads will lead to
irreparable damage.
► Do not make constructional changes to the unit.
► Do not use or store the unit in wet conditions.
► Only use the unit outdoors when sufficiently protected against the influences of the weather.
► Note that the volume flow routed back into the workspace must not exceed 50 % of the supply
air to the installation room. With free room ventilation, a supply air flow of one times the room
volume per hour can be assumed. This means an air exchange rate of one per hour (supply air
flow [m³/h] = Room volume [m³] × air exchange rate [1/h]).
► Check the extraction hoses for damage and soiling at regular intervals, but at least once every
week.
2.2
Obligations of the operator
► Keep non-suitably qualified people out of the work area.
► Ensure that only suitably qualified personnel perform work on the device or system.
Suitably qualified personnel are:
– those who are familiar with the basic regulations on occupational safety and accident
prevention;
– those who have been instructed on how to handle the device;
– those who have read and understood all related documentation;
– those who have been trained accordingly;
– those who are able to recognize possible risks because of their special training, knowledge,
and experience.
2.2.1
Country-specific obligations of the operator
In some countries returning filtered air to the installation room is prohibited on account of residual
health risks.
► Please note the local health & safety requirements.
BAL.0814.0 • V01
Risk of injury due to electromagnetic fields
The device can cause electromagnetic fields to develop.
► Use the device only in industrial areas.
WARNING
2 Safety
EN - 7