xFUME™ ADVANCED HP 230V – CSA
Remove the motors.
5.
Install the new motors. Check that the
6.
motors fit centrally on the bases.
Dispose of the motors in accordance with
7.
local laws and directives. ð 13 Disposal
 (Page 34)
Reverse the steps above to reassemble the
8.
system.
11
Faults and troubleshooting
► Consult the documentation of all components used.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Fault
Extraction volume too low.
Extraction system does not start
up.
Dust is escaping from the dust
collection bin.
BAL.0814.0 • V01
11 Faults and troubleshooting
Cause
Filter elements saturated.
Dust collection bin leaking.
Extraction hose blocked.
Extraction hose faulty.
Tension lock not closed
properly.
The star screws are not
mounted correctly.
Power supply not OK.
Electrical component faulty.
Current clamp is not mounted
correctly.
Dust collection bin leaking.
Correction
► Change filter cartridges.
Replacing filter cartridges
► Check the dust collection bin
and fit it properly. ð 10.2
Emptying the dust collecting
container (Page 27)
► Clean extraction hose.
► Replace extraction hose.
ð 7.1 Attaching the
extraction hose (Page 17)
► Properly close the tension
lock.
► Hand-tighten the star
handles.
► Check and replace as
needed, or contact customer
service.
► Mount the current clamp
properly ð 7.2 Mounting
the Current Clamp
 (Page 18).
► Check the dust collection bin
and fit it properly. ð 10.2
Emptying the dust collecting
container (Page 27)
EN - 31