7 Commissioning
7.2
Mounting the Current Clamp
A mounting clamp is included in the scope of delivery. A second current clamp is optionally
available for the connection of a second fume collection device.
Connect the current clamp cable to the
1.
current clamp port.
Lay the current clamp over the cable
2.
assembly and ensure that the red point on
the current clamp always points in the
direction of the current flow.
Set the <Auto/Manual> switch to <Auto>.
3.
7.3
Attaching the compressed air hose
To prevent a leak at the compressed air
1.
connection, seal the thread of the
compressed air connection with PTFE tape.
Wind the PTFE tape tightening direction
(clockwise).
Screw in the compressed air connection
2.
including sealing ring.
Mount the compressed air hose on the
3.
compressed air connection and connect to
the compressed air supply. Use a
compressed air hose with an inside
diameter of a minimum of 9 mm and a
maximum length of 5 m.
EN - 18
xFUME™ ADVANCED HP 230V – CSA
BAL.0814.0 • V01