10.1
Maintenance and cleaning intervals
The given intervals are for guidance and refer to one-shift operation. We recommend documenting
the checks. At least the test date, the defects found and the name of the tester should be
documented.
Interval
After 2 operating hours or
when the service LED
illuminates
Daily
Weekly
Monthly
After approx. 500 operating
hours
Table 4
10.2
Emptying the dust collecting container
Loosen the star screws on the dust collecting
1.
container.
Pull out the dust collecting container.
2.
Empty the dust collection container in the
3.
dust collecting bag.
Seal the dust collecting bag and dispose of
4.
it in accordance with local laws and
directives. ð 13.2 Disposal of welding dust
(Page 34)
Insert the dust collection bin again.
5.
Hand-tighten the star handles.
6.
BAL.0814.0 • V01
Job
► Run the cleaning process ð 8 Operation (Page 21)
► Change filter cartridges. Replacing filter cartridges
► Empty the dust collection bin. ð 10.2 Emptying the dust
collecting container (Page 27)
► Check the operating hours meter.
► Check the device for visible damage.
► Have motors replaced by a qualified electrician. ð 10.4
Replacing the motors (Page 30)
Maintenance and Cleaning Intervals
10 Maintenance and cleaning
EN - 27