11 Faults and troubleshooting
Fault
Filter dedusting is not working. Compressed air supply not
Service LED illuminates
continuously.
The power LED illuminates after
initialization but the motors fail
to start.
Table 5
EN - 32
Cause
Dust collection bin full.
Tension lock not closed
properly.
The star screws are not
mounted correctly.
OK.
Filter cartridges not inserted
correctly.
Rotary nozzles tilted or
damaged.
End caps of the rotary nozzles
loose or fallen off.
Filter cartridges or filter
membranes are defective/
saturated.
Control board defective.
Power relay defective
Faults and their Correction
xFUME™ ADVANCED HP 230V – CSA
Correction
► Empty the dust collection
bin. ð 10.2 Emptying the
dust collecting container
(Page 27)
► Properly close the tension
lock.
► Hand-tighten the star
handles.
► Check the compressed air
supply and replace if
necessary.
► Check filter cartridges for
correct placement and insert
correctly if necessary.
Replacing filter cartridges
► Check the rotary nozzles
and contact customer
service if necessary.
► Check the top and bottom
end caps of both rotary
nozzles and contact
customer service if
necessary.
► Set the <On/Off> switch to
<Off> to clean the filter
membrane.
The filter membranes are
cleaned twice.
► Change filter cartridges.
Replacing filter cartridges
► Check and replace the
control board as needed, or
contact customer service.
► Check and replace the
power relay as needed, or
contact customer service.