10 Maintenance and cleaning
10.4
Replacing the motors
Loosen the screws (4×) and remove the
1.
cover.
Remove the screws (2x each) and the motor
2.
covers.
Release the grounding cable from the
3.
terminal clamps.
Remove the electric blade terminals.
4.
EN - 30
Electric shock due to electronic component damage
When replacing the motors, electrical connections must be disconnected and
reconnected. Fatal electric shock may occur if electronic components become
damaged or improperly uninstalled in the process.
► The motors should be replaced only by a qualified electrician.
Electric shock due to damaged or improperly installed cable
The use of damaged or improperly installed cables may result in a potentially fatal
electric shock.
► Check all live cables and connections for proper installation and damage.
► Have any damaged, deformed, or worn parts replaced by a qualified electrician
only.
xFUME™ ADVANCED HP 230V – CSA
WARNING
WARNING
BAL.0814.0 • V01