All operating elements and connections de -
GB
scribed can be found on page 2.
1 Operating Elements
and Connections
Each monitor has its own operating elements and
audio / video jacks. The power supply of the com-
plete monitor unit is made via a common connec-
tion.
1
Button MENU / EXIT
– to call the on-screen menu
– to exit the on-screen menu or a page of the
menu and to deactivate on-screen inser-
tions (e. g. volume adjusting scale)
2, 3 Button SOURCE to call the source selecting
list
Button AUTO to release an automatic picture
adjustment for the source at the VGA input (9)
The functions
select a source from the source list, in the on-
screen menu they serve to select menu items
on a menu page.
4, 5 Button VOL
– to reduce the volume
Button VOL /SELECT
– to increase the volume
– to confirm a source selection from the
source list
In the on-screen menu the buttons serve to
select the menu pages and to adjust the menu
items (change the values or select adjusting
options). For some menu items a submenu
can be called or a function can be activated
with the button .
6
Button
mode or to switch it on
7
Power indication
Red
monitor in stand-by mode
Green
monitor switched on
Yellow
DPMS power saving mode
(
8
HDMI
TM
input (19-pole jack type A)
9
VGA input (15-pole Sub-D jack)
10 Composite video inputs (BNC jacks)
11
Feed-through outputs (BNC jacks), each for
the video signal of the BNC input (10) located
on their left
10
and
of the buttons serve to
to switch the monitor to stand-by
menu item
DPMS
, chapter 7.5.2)
12 Stereo audio input (RCA jacks): can alterna-
tively be used for the source at the input
VIDEO 1 or VIDEO 2 (10) or for the source at
the input S-VIDEO (13)
13 S-Video input (mini DIN jack, 4-pole)
14 Stereo audio input (3.5 mm jack) for the source
connected to the VGA input (9)
15 Power supply jack for connection of the power
supply unit provided
2 Safety Notes
The units (monitor unit and power supply unit) cor-
respond to all relevant directives of the EU and are
therefore marked with
WARNING The power supply unit is supplied
with
hazardous
Leave servicing to skilled personnel
only. Inexpert handling or modifica-
tion of the power supply unit may
cause an electric shock hazard.
It is essential to observe the following items:
G
The units are suitable for indoor use only. Protect
them against dripping water and splash water,
high air humidity, and heat (admissible ambient
temperature range 0 – 40 °C).
G
Do not place any vessels filled with liquid, e. g.
drinking glasses, on the units.
G
To prevent heat accumulation in the unit, always
place the monitor unit so that a sufficient air cir-
culation is ensured (distance to the wall > 10 cm).
The air vents must not be covered.
G
Do not set the monitor unit into operation, and
immediately disconnect the mains plug of the
power supply unit from the mains socket if
1. there is visible damage to a unit or the mains
cable,
2. a defect might have occurred after a drop or
similar accident,
3. malfunctions occur.
The units must in any case be repaired by skilled
personnel.
G
Never pull the mains cable to disconnect the
mains plug from the mains socket, always seize
the plug.
G
For cleaning the power supply unit only use a
dry, soft cloth. To clean the monitors, it is also
possible to use a soft cloth slightly damp. Never
use chemicals or aggressive detergents. Discon-
nect the mains plug prior to cleaning.
.
mains
voltage.