Problem
Causes
High Evaporator
Temperature Alarm
EVAPORATOR
HIGH
Evaporator fun out of
TEMPERATURE
order.
Heating elements
always inserted..
Alarm Safety
THERMAL
Thermostat Steam
SWITCH
Generator
OPEN
Open Door signal
DOOR
Door opening
Problem
NO
Interface communication error user- control
COMMUNICATION
module.
POWER
Interface compatibility error user- control
BOARD
module.
INCOMPATIBILITY
The
exceeded the first limit imposed.
CONDENSER
OVERHEAT
The
exceeded the second limit imposed.
COMPRESSOR.
SHUTDOWN
The buzzer is active. The buzzer
can be silenced pressing any key.
The temperature detected by the
probe is higher than the set value
(60°C)
The buzzer is active. The buzzer
can be silenced pressing any key.
Water connection not made.
Water inlet valve damaged..
The buzzer is active. The buzzer
can be silenced pressing any key.
Causes
temperature
of
the
The condenser fan will be turned on
The alarm output will be activated.
temperature
of
the
It will not be allowed either select or start
any operating cycle.
If the error occurs during an operating cycle,
the cycle will be interrupted
The alarm output will be activated.
Effects
condenser
has
condenser
has
 Air the room.
 Clean the condenser.
 Check that the fans are working
properly.
19
ENGLISH
Solutions
Replace the evaporator fan
Verify the heating element
connection
.
Contact the after-
sales service.
Perform the connection of
the boiler to the water
supply using the supplied
pipes.
Contact the after-
sales service.
The signal automatically
returns once the door is
closed.
Solutions
Contact the after-sales
service.
Contact the after-sales
service.
Contact the after-sales
service.