Problem
The electronic board remains
off.
The machine does not heat
correctly
Insufficient humidity in
proving chamber
Deformed water inlet pipe
(high pressure inside boiler).
Causes
Power supply cable incorrectly connected.
Interrupted fuses
Protective Klixon (PTRC) interrupted.
Check heating element
Evaporator fan blocked
Closed water cock
Clogged water filter
Water inlet electrovalve malfunctioning
Vapour inlet electrovalve malfunctioning
Boiler resistance not working
Check humidity sensor
Malfunctioning sensor or level control
Vapour inlet electrovalve malfunctioning
Blocked boiler safety valve
No pressure reducer
Malfunctioning sensor or level control
17
ENGLISH
Solutions
Check the electric
connection
Check and replace fuses
Check and replace the
component.
Check connections and
resistance
Contact the after-
sales centre.
Open water inlet cock
Clean filter
Replace component
Check and replace the
component.
Check and replace the
component.
Check if the value of the
probe is correct
Check and replace the
component.
Check and replace the
component.
Check and replace the
component.
Check and insert the
reducer inside water inlet
valve
Check and replace the
component.
GB