Problem
The refrigerator unit does not start
GB
The refrigerator unit functions
continuously, cooling insufficiently
The refrigerator unit does not stop
Presence of ice inside the
evaporator
Appliance noise
Causes
End of defrosting
No Voltage
If the condenser fan runs,
intervened klixon the
compressor
Other causes
Room too hot
Dirty condenser
Insufficient door sealing
Check the correct functioning
of the thermostatic valve
Insufficient quantity of
refrigerant gas
Hot gas valve partially open
(only 60x40 version)
Resistances always inserted
Condenser fan at a standstill
Evaporator fan at a standstill
Probe faulty
Thermostat fault
Appliance not level
Hot gas valve failure (only
60x40 version)
Resistances not functioning
Check parameters
Check steam generator
Check the defrost probe
Insufficient door sealing
Persistent vibrations
16
Solutions
It restarts after a pause of three
minutes.
Check plug, sockets, fuses and
electric mains
Replace the compressor or electrical
box
Contact the after-sales
centre.
Air the environment
Clean the condenser
Check the gaskets
control the valve adjustment.
Contact the after-sales
centre.
Contact the after-sales
centre.
Contact the after-sales
centre.
Contact the after-sales
centre.
Contact the after-sales
centre.
Contact the after-sales
centre.
Contact the after-sales
centre.
use the adjustable feet to level
Contact the after-sales
centre.
check defrosting activation (only on
models with electric defrosting)
60x80 BTversione - P73=0
Verify that the steam generator is not
always on
Check the value of the probe
check the gaskets
check that there is no contact
between the appliance and other
objects inside or outside