Wear hearing protection!
Vibration emission value
Vibration values determined in accordance with ISO 28927-12 and
EN 12096:
2
a
= 3.34 m/s
h
Uncertainty K = 0.87 m/s
WARNING!
The noise emission levels specified in these instructions have
been measured in accordance with the standardised measur-
ing procedure specified in ISO 15744 and can be used to
make equipment comparisons. The noise emission values vary
in accordance with the use of the compressed air tool and may
be higher than the values specified in these instructions in some
cases. It is easy to underestimate the noise emission load if the
compressed air tool is used regularly in a certain manner.
NOTE
For an accurate estimate of the noise emission load during a
certain working period, the times during which the appliance is
switched off or is running but not actually being used must also
be taken into consideration. This can significantly reduce the
noise emission load over the total working period.