Battery Care
!
and prolong your battery life, please follow the simple steps below:
UNDER NORMAL DAILY USAGE:
Re-charge the machine FULLY after each use regardless of machine operation
time.
Do not leave the machine in a discharged state.
Charging Light Sequence
HGB 3045/55, HBG 3045/55 TGB 3045/55
TGB 4045/100, 4055/100, 4055/100T
Under abnormal use;
i.e. leaving the machine without charging for a period of time, we advise that you follow these steps:
If the machine will be standing unused for a period of 30 days or more, then batteries
must be fully charged and battery fuses removed using the maxi fuse-puller provided,
prior to this period.
Batteries should be re-charged every three months.
Charge fully the day before you start using the machine again.
To ensure your machine remains at its maximum efficiency
Signal (LED)
Red LED on
First Phase (constant current Mode)
Yellow LED on
Second Phase (Constant Voltage Mode)
Green LED on
Third Phase (Constant Voltage Mode) Charge Complete
Charging System Error
Red LED flashing
Unsuitable battery or charging malfunction safety timer exceeded
followed by Pause
Internal short circuit, disconnect from power supply, switch power supply,
OFF then ON, to restart the charging cycle
Yellow LED flashing
Battery not connected
Re-charge the machine fully after its last use. Do not leave the machine in a discharged state.
Meaning
25
!