ALWAYS ENSURE THAT THE MACHINE IS SWITCHED OFF PRIOR TO ANY
MAINTENANCE USING THE MASTER CONTROL ON/OFF KEY.
REMOVE THE KEY PRIOR TO ANY MAINTENANCE OPERATION.
1
3
Located under the left hand side is a clean water filter, make sure
After use, empty waste water tank
A
using emptying hose and flush out
with clean water.
A
Next remove floor tool vacuum
B
hose and flush out with clean water.
Next empty clean water tank, using
C
emptying hose and again flush out
with clean water.
Whilst pressing in the top tank hood
toggles, remove the hood. (Fig.1)
The hood also has a sealing-rubber which
should be examined at every clean-down.
Rinse using clean water, avoiding the
vac filter.
Remove the filter fitted into the separator
and flush with clean-water (Fig.2)
IMPORTANT
Remove vac filter and clean if required
(keep dry).
Never use the machine without the
recommended filter as it may cause
damage to the machine.
Remove debris basket filter and rinse
using clean water, and refit. (Fig.3)
IMPORTANT If the debris basket is
allowed to become clogged, vacuum
performance can deteriorate.
the clean water tank is empty before removing this filter.