Protection function
High temperature protection: The electronic temperature sensor on the
control panel will transmit the real-time temperature to the chip of the
control p anel. T he control s ensor st arts p rotection w hen t he e lectronic
temperature sensor gauge the current temperature is higher than a
certain value, to reduce the heating level of the cooking zone currently,
and resumes the heating level after the temperature drops.
Residual heat protection: When the whole appliance stops heating, the
digital t ube of t he relative heating z one w ill di splay h igh t emperature
warning symbol "
too high, please do not touch to avoid getting burned.
PCB board fault codes and solutions
When a PCB board failure occurs, the timer digital tubes on the display
panel always display the fault code, and all the burners that are being
heated stop heating, and automatically return to the shutdown state after 1
minute. For the burners that have been worked, t he corresponding d igital
tube continues to display the high temperature warning sign " ". When the
fault code appears, please refer to the scheme in the following table to
solve.
Fault code
The display board does not
E1
receive the signal of power
supply board.
E2
The power supply board does
not receive the signal of
display board.
", indicating that cooking surface temperature is
Type of fault
EN-21
Solution
The communication line
failure of power supply
board or display board can
cause communication
anomalies.
Replace the display board
first. If the fault persists,
replace the power supply
board.