OUTPUT OPTIONS
Optionally, model MICRA-M can incorporate one or several output options for control or communication:
Communication options
RS2 Serial RS232C
RS4 Serial RS485
ETH Ethernet
Control options
NMA Analog 4-20 mA
NMV Analog 0-10 V
2RE 2 Relays SPDT 8A
4RE 4 Relays SPST 5A
4OP 4 NPN outputs
4OPP 4 PNP outputs
All mentioned options are optoisolated with respect to input signal and power supply.
The output cards are easily installed on the meter's main board by means of plug-in connectors and each one acti-
vates its own programming modules that provides complete software configuration.
Additional capabilities of the unit with output options:
Control and processing of limit values via ON/OFF logic outputs (2 relays, 4 relays, 4 NPN outputs or 4 PNP
outputs) or proportional output (4-20mA, 0-10V).
Communication, data transmission and remote programming via serial interface.
For more detailed information on characteristics and mounting, please refer to the specific manual supplied with each
option.
PRESS ON BOTH SIDES
TO EXTRACT THE CIR-
CUITS WITH THE FRONT
PANEL COVER
The 2RE, 4RE, 4OP y 4OPP options are alternative and only one of them can be placed into the connector M1.
The RS2, RS4 and ETH options are also alternative and only one of them can be placed into the connector M2
The NMA or NMV option is placed into the connector M3.
Up to three output options can be present at the same time and operate simultaneously:
One analog (ref. NMA or ref NMV)
One RS232C (ref. RS2), RS485 (ref. RS4) or Ethernet (ref. ETH).
One 2 relays (ref. 2RE) or 4 relays (ref. 4RE) or 4 NPN (ref. 4OP) or 4 PNP (ref. 4OPP) outputs.