Filter of ponderated average. The value will be modified through the
set in reverse order the cut-off frequency of the low pass filter, getting the filter deactivated for 0


value. Not available when the instrument is configured for temperature measurement.
to
Round
Will take each one of the values by pressing successively on the
be no round, 05 will round the display value at 0 o 5, and with 10 will round at 0 o 10. Just
like the previous variable not available when the instrument is configured for temper-

ature measurement.
Display brightness level selection.
Brightness
Hi: high brightness
Lo: low brightness
Display color selection between green, red or amber is possible for both RUN and PRO

modes.
Allows choosing an operative mode with an up to 45% of ENERGY SAVING*
Eco
on: After a programmable time without pressing any key, display will turn off leaving only the
right decimal point flashing; all functions remain active. Display will be again active after
pressing any key.

oFF: Deactivates the function.
*Measured at 230V AC power supply, display 100.00, amber colour and with no options.
Input Error
YES: If input signal is lower than the minimum, display will show "- - - - -".
No: Without indication.
(For more information see specifications on page )
Tare Mode
By pressing
to tare. Each time you accede this menu, the tare value stored in the instrument memory will
reset, and as usual when the instrument is in this state, the TARE led will stay off. Once se-
lected the operation mode, we go to the "RUN" mode, from where will be made the tare pro-
cess.
In mode tArE1 the instrument, pressing on the

unless it is over scaled, the TARE Led will light up and from this moment the value displayed
is the net value, i.e., the measured value minus the value stored in the tare. If having the
instrument a tare, we press one more time on the same key, the value displayed at this mo-
ment will add up to the tare previously stored, the addition of both will make the resulting
tare. By pressing this key during 3s., the instrument will set the tare value to zero, and the
TARE led will stop light up, indicating the GROSS value.
In this mode, the

however the instrument operation the same as in the previous mode. The edit menu Hill be
accessed from the "RUN" mode, by pressing on the
Following the diagram.
In this mode, a variable, that we will call net value will be edited, acceding now also from

"RUN", after pressing on
first case, will have no effect until we press on the
mode, the Led TARE will be then activated. The value stored in tare is now the difference be-
tween the value measured by the instrument when the tare action occurred and the net val-
ue. The value resulting from the difference between the measured value and the tare value
will be the same. It will be necessary to enter in the programming menu and pass by "CndSP"
> "ModtA" to reset the tare.
Example:
A process using a liquid contained in a tank from which are known according to the manufacturer specifications
the gross weight, 100 Kg, and the net weight 75 Kg. I n the weighing process is used a load cell connected to a
Micra M instrument and we need to know the liquid net weigh in each instant of the process. By selecting this tare
mode, the net value would be introduced via edition following the enclosed diagram. When the instrument is
measuring the tank, totally full of liquid, this would be 100 Kg, the instrument is tared, indicating then 75 Kg. and
the quantity of remaining liquid in the tank while it is getting emptied.
KOSMOS SERIE
key, we can select the mode in which the instrument will treat the process
key has no effect. The tare value is now introduced manually, being
during 3 s following the diagram. The tare action, as in the
www.ditel.es
MICRA-M
key. This parameter will
key. with 01 there will
key, stores the current displayed value
key during 3s.
key, being the instrument in "RUN"