MANUAL FUNCTION

If the instrument is in OFF position the press button laser lines or laser dots once to enter into the
MANUAL mode; the ON/OFF LED is illuminated, the MANUAL LED is blinking, the laser lines / laser
dots are on. Now the instrument can be used in slope mode, the compensator alarm is off. All lines and
dots can now be switched as described earlier. Switch off the MANUAL function with the button laser
lines / laser dots.
D
USE WITH RECEIVER
To prolong the working range or at unfavourable light conditions CrossPointer5 SP can be used with the
optional receiver FR 55-M (not included in this kit).
Switch on the desired laser lines and press the button pulse function at CrossPointer5 SP (the LED for
the corresponding lines flashes).The selected laser lines can now be deteced by the receiver
(the visibility of the laser lines is weaker in this mode).
By use of the receiver the working range can be extended up to 80 meters. For more detailed informati-
on please see the user manual of FR 55-M (ref. no. 500520).
Press the button pulse function again to quit this mode.