Do not place anything on the unit.
3.2 Handling of the Indoor Unit
WARNING
!
Before the installation and commissioning, do not place any irrelevant materials inside the indoor
unit and ensure there are no sundries in the indoor unit as it may lead to fire or accident.
NOTICE
During handling, do not damage the thermal insulation materials on the surface of the unit.
4. Indoor Unit Installation
Install the indoor unit as per national and local regulations.
DANGER
!
Do not install the indoor unit in an inflammable environment and keep it far away from combustive
sources or explosive substances.
Do not install the indoor unit in the laundry.
The indoor unit should be positioned in a place where:
(1) both the air inlet and air outlet are unobstructed,
(2) the unit is not exposed to direct sunlight,
(3) drainage occurs easily,
(4) the unit is away from sources of heat or steam,
(5) there is no source of machine oil vapor (this may shorten the indoor unit service life),
(6) cool/warm air is circulated throughout the room,
(7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they
may affect the remote controller range.
WARNING
!
Do not install the indoor unit outdoors as it may lead to electric leakage or shock. Mount with the
lowest moving parts at least 8ft(2.5m) above floor or grade level.
4.1 Supplied Accessories
Ensure that the indoor unit is accompanied by the following accessories:
NOTICE
Contact the dealer if the machine is not accompanied by these accessories in transport.
The number of random attachments is detailed at the end of the packing list.
Accessory
Q'ty
Fixed washer
8
Screw
16 For flange fixation Magnet Ring
Pipe Clamp
2
Table 4.1 Accessories
Accessory
Purpose
For the body
suspension
Condensate pipe
fixation
For flexible
condensate hose
Cord Clamp
connection
4. Indoor Unit Installation
Q'ty
For drainage pipe connection (only
1
when choosing the optional drainage
pump)
For anti-electromagnetic interference
1
of transmission wires between outdoor
and indoor units
For Fixing Thermal Insulation for
1
Refrigerant Pipings
-5-
Purpose