• Avoid accidental start-up of the product: when in-
serting the plug into the socket, do not press the on/
off switch.
• Use the product in the way that is recommended in
this operating manual. This is how to ensure that
your product provides optimum performance.
• Keep your hands away from the working area when
the product is in operation.
• Before performing setting or maintenance work, re-
lease the on/off switch and pull out the mains plug.
WARNING
This power tool generates an electromagnetic field
during operation. This field can impair active or pas-
sive medical implants under certain circumstances. In
order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.
7
Technical data
Compound mitre saw:
AC motor
Nominal power S1
Operating mode
Idle speed n
0
Carbide saw blade
Number of teeth
Maximum tooth width of
the saw blade
Pivot range
Mitre cut
Saw width at 90°
Saw width at 45°
Saw width at 2 x 45°
(double mitre cut)
Protection class
Weight
Laser:
Laser class
Laser wavelength
Power of laser
Battery:
Battery type
Nominal capacity
Rated voltage
Size
Subject to technical changes!
8
|
GB / IE / NI / CY / MT
220 - 240 V~ 50 Hz
1200 Watts
S6 25%* 1500 W
4900 rpm
ø 210 x ø 30 x 2.6 mm
48
3 mm
-45 ° / 0° / +45 °
0° to 45° to the left
120 x 60 mm
80 x 60 mm
80 x 35 mm
II /
(double insulation)
approx. 6.44 kg
2
650 nm
< 1 mW
LR03
2000 mAh
1.5 V
Micro AAA
Operating mode S6
Uninterrupted periodic operation. The mode comprises
of a start-up period, a time with constant load and an
idle time. The operating time is 10 mins, the relative du-
ty cycle is 25% of the operating time.
The workpiece must have a minimum height of 3
mm and a minimum width of 10 mm. Make sure
that the workpiece is always secured with the
clamping device.
Noise data
WARNING
Noise can have serious effects on your health. If the
machine noise exceeds 85 dB, please wear suitable
hearing protection for you and persons in the vicinity.
The noise and vibration values have been determined in
accordance with EN 62841-1.
Sound pressure level L
pA
Uncertainty K
pA
Sound power level L
wA
Uncertainty K
wA
The specified noise emission values have been mea-
sured in accordance with a standardised test procedure
and can be used to compare one power tool with anoth-
er.
The specified device emissions values can also be used
for an initial estimation of the load.
WARNING
The noise emission values can vary from
the specified values during the actual use
of the power tool, depending on the type
and the manner in which the electric tool is
used, and in particular the type of work-
piece being processed.
Try to keep the stress as low as possible. For example:
Limit working time. In doing so, all parts of the oper-
ating cycle must be taken into account (such as times
in which the power tool is switched off or times in
which it is switched on, but is not running under a
load).
8
Unpacking
• Open the packaging and carefully remove the prod-
uct.
• Remove the packaging material, as well as the pack-
aging and transport safety devices (if present).
• Check whether the scope of delivery is complete.
91.6 dB
3 dB
104.6 dB
3 dB