4)
Check that calibration is completed and
remove the test chart from the original glass.
* When calibration fails, the screen shown
in the figure is displayed. Since the test
chart may have deviated from the
appropriate position, set it correctly and
perform calibration again.
11. The automatic gamma adjustment for 1200
dpi printer is performed.
* Only for e-STUDIO2050C/2550C.
1)
Place A4 or LT paper in the drawer.
2)
Press [OK].
The test chart for calibration is output.
3)
Set the test chart on the original glass and
press [OK].
The scanner reads the original and
calibration starts automatically.
4)
Check that calibration is completed and
remove the test chart from the original glass.
* When calibration fails, the screen shown
in the figure is displayed. Since the test
chart may have deviated from the
appropriate position, set it correctly and
perform calibration again.