Appendix 3 - Free Chlorine Measure Cell - aqua Technopool3 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TECHNOPOOL3
Dosing systems for swimming pools
13.0 APPENDIX 3 – FREE CHLORINE MEASURE CELL (CL)
Operating temperature: 0 to 45° C.
Water conductivity: > 10 μ S/cm.
Maximum working pressure: 0.5 bar.
Output signal: 4÷20 mA current proportional to the ppm reading.
Power supply: 12 Vdc ± 1 V.
Electrolyte life: approx. 3 months (or less if the chlorine concentration is high).
Membrane life: approx. one year (depends greatly on the quality of the water).
A device must be used for the calibration, in order to determine the content of free chlorine according to the
DPD method (it is recommended to use a photometric instrument).
The reading of the free chlorine measure cell supplied is slightly affected by the variations in pH (range
4÷12 pH).
Description of the chlorine electrode
1. PG7 cable gland.
2. Cover.
3. O-Ring.
4. 2-pole terminal for the electrical connection.
5. Electrode holder.
6. Counter electrode (stainless steel).
7. O-Ring.
8. Reference electrode.
9. Measure electrode.
10. Transparent ring.
11. Membrane cap.
12. Membrane covering.
13. Membrane.
14. Valve.
Installation procedure
Probe polarization is required on the first installation. After having connected the probe to the
Technopool3, immerse it in a container of water at 0 ppm and leave it for an hour.
The membrane is extremely sensitive! When removing or tightening the membrane cap, make sure
the membrane is not damaged with the high or low pressure.
ADSP7000570
 Connect the wires to the terminal (4). (+ brown / - blue).
 Tighten by hand (2) until the O-Ring (3) isolates the system.
 Close the PG7 cable gland securely (1).
rev. 1.6
Electrical connections
09/01/2014
APPENDIX 3
ENGLISH
64/136

Publicité

Table des Matières
loading

Table des Matières