LARM SIGNAL
Alarms are always signalled by the LCD display with the wording Alr.
Moreover, the two LEDs light on to indicate that the pH or redox/Chlorine/Hydrogen peroxide pump has an alarm
situation in progress.

7.0 WINTER PAUSE

It is recommended to work the system with tap water to clean the tube and avoid chemical attacks during the pause
period. Probes must be removed from the installation, during the winter pause. The protective cap must be filled
with 1/3 of water and placed on the probe edge.
Chlorine electrode (see Appendix 3 for references)
Remove the CI electrode from the probe holder, loosen the cap and remove the electrolyte from the membrane-
holder cap (11) and from the cap (15) only for ADELCLJ15, rinsing it under a little running water. Then dry
everything, paying attention not to damage the membrane and the surface of the electrode. Once the electrode is
dry, place it in its package for the winter break.
Hydrogen peroxide electrode (see Appendix 4 for references)
Remove the HP electrode from the probe holder, loosen the membrane cap and remove the electrolyte, clean both
the membrane cap and the electrode with water. Then dry everything, paying attention not to damage the
membrane and the surface of the electrode. Close the membrane cap without tightening and place the electrode in
its package for the winter break

8.0 OPERATIONS TO CARRY OUT AT THE BEGINNING OF THE SEASON

 It is recommended to install a new probe at the beginning of the season, to prevent the system from
malfunctions.
 Once replaced the electrode or when restarting the system, repeat the calibration procedure.
 It is recommended to perform the calibration procedure of the Chlorine probe. If calibration is no longer
possible due to the indication being too low, rub the tip of the measure electrode with the supplied sand
paper and if necessary, replace the electrolyte.
 It is recommended to perform the calibration procedure of the hydrogen peroxide probe. If calibration is
no longer possible due to the indication being too low, rub the tip of the measure electrode with the
supplied sand paper and if necessary, replace the electrolyte.

9.0 RETURN TO THE AFTER-SALES SERVICE

The material must be sent back in its packaging with all its original protection devices before the guarantee period
is completed.
The system must be clean and the chemical product removed from the tubes.
The measure electrode must be placed in its original packaging and protected with the cap full of water.
The manufacturer declines any responsibility regarding damages caused by transportation, if the aforementioned
conditions are not respected.