TECHNOPOOL3
Dosing systems for swimming pools
1.2
C
ONFORMITY
Our pumps are manufactured according to General Standards in force and in compliance with the following
European Directives:
n° 2004/108/CE " e s.m.i.
n° 2006/95/CE "DBT Low Voltage Directive" e s.m.i.
n° 2011/65/UE , 2012/19/UE "direttive RoHs e WEEE" e s.m.i.
To achieve the best and ensure the longest durability of the system, read and follow the rest of the manual
especially the part relative to maintenance.
The manufacturer declines any responsibility for damages on the system caused by non-qualified
personnel.
1.3
T
ECHNICAL FEATURES
Back-lit LCD display 2x16.
Red LED (pH) pH alarm signal.
Red LED (Rx-ppm) redox alarm signal (only for Time/pH/Rx and pH/Rx Technopool3 systems).
Red LED (Rx-ppm) chlorine alarm signal (only for pH/ClJ Technopool3 systems).
Red LED (Rx-ppm) hydrogen peroxide alarm signal (only for pH/HP Technopool3 systems).
Main ON/OFF switch.
Dose enable switch for each pump.
Solenoid valve output (dry contact, no voltage).
Flow sensor input.
Three inputs for level probes.
An input for temperature probe PT 100.
A BNC input for pH electrode.
A BNC input for redox electrode (only for Time/pH/Rx and pH/Rx Technopool3 systems).
A HIRSCHMANN input for chlorine electrode (only for pH/ClJ Technopool3 systems).
A HIRSCHMANN input for hydrogen peroxide electrode (only for Technopool3 pH/HP systems).
Alarm repetition output 24VDC.
Hereunder are the maximum pump capacities:
4 L/h @ 1 bar, Santoprene® tube.
1.4
E
LECTRICAL FEATURES
Power supply: 100÷240 VAC 50/60 Hz and consumption (max): 14 W.
pH Range: 0.00...14.00.
Redox Range: 0...1000 mV (only for Time/pH/Rx and pH/Rx Technopool3 systems).
Chlorine range: 0.00...20.00 ppm (only for Technopool3 pH/ClJ systems).
Hydrogen peroxide range: 0.0...500.0 ppm (only for Technopool3 pH/HP systems).
Temperatura range (PT100): 0...100° C.
1.5
P
ACKAGING CONTENT
Technopool3 System.
Instruction manual.
Wall mounting bracket.
Screws and wall plugs for wall fixing.
pH 4 buffer solution.
pH 7 buffer solution.
475mV buffer solution (only for Time/pH/Rx and pH/Rx Technopool3 systems).
pH electrode with 5 m cable.
Redox electrode with 5 m cable (only for Time/pH/Rx and pH/Rx Technopool3 systems).
Chlorine electrode with 5 m cable (only for pH/ClJ Technopool3 systems).
Hydrogen peroxide electrode with 5 m cable (only for pH/HP Technopool3 systems).
3-wire temperature probe PT100 with 5 m cable.
DN50 collars (4pcs).
Suction filter (2 or 3 pcs).
Injection valve (2 or 3 pcs).
Probe holder (1 or 2 pcs).
Suction and delivery tubes.
ADSP7000570
rev. 1.6
1 L/h @ 3 bar, Silicone tub
09/01/2014
INTRODUCTION
ENGLISH
37/136