TECHNOPOOL3
Dosing systems for swimming pools
5.2
R
ESTORE THE DEFAULT PARAMETERS
By activating this function, all programmed data will get lost!
6.0 ALARMS
The system is equipped with the following alarms:
Level alarm, with 3 seconds of hysteresis; this alarm interrupts the operation of the relative pump.
Flow alarm, with 3 seconds of hysteresis; this alarm interrupts the dosing of the system.
Dosing enabling alarm, with 3 seconds of hysteresis; this alarm interrupts the dosing of the system.
pH measure alarm: The system is equipped with a pH reading alarm. If the value of the pH is lower
than 5 and higher than 9, the system stops the pumps. If the value of pH is lower than 5 or higher than
9, it is recommended to control the probe and the quality of the water.
Dosing Alarm: product dose with no effect (with no variation in the pH or Rx or Cl or HP reading). The
dosing alarms can only be removed by restarting the system (use the ON/OFF switch) or automatically,
when the measure nears the setpoint.
ADSP7000570
The restoration of the factory parameters is enabled (refer to appendix 1). The
system asks if you are sure to proceed.
Press keys ▼▲ to select the two options and Enter to confirm.
rev. 1.6
09/01/2014
ALARMS
ENGLISH
58/136