TECHNOPOOL3
Dosing systems for swimming pools
1.0 INTRODUCTION
Technopool3 is an integrated system able to control up to three peristaltic pumps and a solenoid valve control
relay, for the automatic management of water treatment in the swimming pool.
Refer to appendix 2 for Technopool3 range.
Peristaltic pumps are controlled in the following ways:
P1 Pump: for a cyclic dosing of an anti-algae product.
A timer is set to program the dosing schedule of the required product and the quantity of product in ml; the
programmed quantity can be modified proportionally to the water temperature reached during the latest
dosing.
pH Pump: for dosing the pH corrector.
The setpoint of the pH value is set to be maintained in the swimming pool.
P2 pump can be managed in two ways, depending on the type of system:
Pump Rx: for dosing the disinfectant.
The setpoint of the redox value is set to be maintained in the swimming pool.
Pump CI: for dosing the disinfectant.
The setpoint of the chlorine value is set to be maintained in the swimming pool.
Pump HP: for dosing the disinfectant.
The setpoint of the hydrogen peroxide value is set to be maintained in the swimming pool.
P2 Pump: for a cyclic dosing of a product.
A timer is set to program the dosing schedule of the required product and the quantity of product in ml; the
programmed quantity can be modified proportionally to the water temperature reached during the latest
dosing.
On the other hand, the solenoid valve of the control relay, used for dosing the chlorine tablets, can be programmed
in two ways:
cyclic
Opening (ON) and closing (OFF) schedule of the relay are fixed or proportional to the temperature of the
water reached during the latest dosing.
ON/OFF
Opening (ON) and closing (OFF) schedule is controlled by the redox/chlorine or hydrogen
therefore, it depends on the setpoint setting with a fixed hysteresis of 10 mV (redox), 0.05 ppm (chlorine) and 5
ppm (hydrogen peroxide).
1.1
W
ARNINGS
This manual has the purpose to provide all information required for a correct installation and maintenance of the
system, to ensure best results during its operation.
For this reason, the instructions described below must be carefully read, as they supply all information required for
the installation, use and maintenance safety.
Store this manual with care so it can be consulted when necessary.
Ensure the integrity of the system at the delivery; in case anomalies are detected, contact specialised
personnel, before carrying out any intervention.
Before proceeding with the installation, ensure the data on the plate correspond to the specifications of the
electric system.
Do not operate with bare feet and/or hands.
Prevent the system from the exposure to atmospheric agents.
Only specialised personnel is allowed to perform any operation on the system.
In case of anomalous operation, immediately switch off the system and contact the After-Sales Service for
the required repair actions.
For a correct operation, use original accessories and spare parts.
The manufacturer declines any responsibility with regard to damage caused by improper use or use of non-
original accessories or spare parts.
The electrical system must be in compliance with the regulations in force of the country where the system
is located.
The room temperature where the system is installed must never exceed 45°C.
ADSP7000570
rev. 1.6
09/01/2014
INTRODUCTION
ENGLISH
peroxide;
36/136