TECHNOPOOL3
Dosing systems for swimming pools
4.3
S
ETTING OF THE CYCLIC DOSING
Depending on whether the temperature has been programmed, the following parameters must be set for the pump
operation for the cyclic dosing:
Temperature OFF (disabled):
Manual temperature or with PT100:
Qty first Prod. – Qty first P. TMax – Frq. first Prod. – Hour first. Prod.
Enter the installer menu, select option Set Point/Timer and press key Enter.
Temperature OFF (disabled):
Manual temperature or with PT100:
ADSP7000570
P1) –
(
PUMP
IT IS NOT DISPLAYED ON P
Qty first Prod. – Frq. first Prod. – Hour first. Prod.
Qty first Prod.
Indicates the quantity to be dosed in ml or litres.
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set are 0÷999 ml or 1.0÷9.9 litres.
Frq. first Prod.
Indicates the activation frequency of the pump dosing, which can be set in hours
or days.
Values that can be set are 1÷23 hours or 1÷7 days (d).
Hour first Prod. (only if the frequency has been programmed in days)
Indicates the activation hour. If it is left in Auto, the activation occurs
immediately after the programming.
Values that can be set are 0÷23 hours or Auto.
Example:
First Prod. Qty = 400 ml
First Prod. Freq. = 2 d
First Prod. Hour = 13
The system activates P1 pump to dose 400 ml of product every two days at
h13.00.
Qty first Prod.
Indicates the quantity to be dosed in ml or litres.
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set are 0÷999 ml or 1.0÷9.9 litres.
Qty first P. Tmax
Indicates the quantity to be dosed (0÷999 ml or
1.0÷9.9 litres) to the programmed maximum temperature (23÷36°C)
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set are 0÷999 ml or 1.0÷9.9 litres.
Frq. first Prod.
Indicates the activation frequency of the pump dosing, which can be set in hours
or days.
Values that can be set are 1÷23 hours or 1÷7 days (d).
Hour first Prod. (only if the frequency has been programmed in days)
Indicates the activation hour. If it is left in Auto, the activation occurs
immediately after the programming.
Values that can be set are 0÷23 hours or Auto.
rev. 1.6
H/R
,
H/C
J
X
P
L
AND P
09/01/2014
QUICK PROGRAMMING
ENGLISH
H/HP
3
TECHNOPOOL
46/136