TECHNOPOOL3
Dosing systems for swimming pools
The quantity of product to be dosed is proportional to the temperature reached during the latest dosing, according
to the diagram below:
To calculate exactly the dosing, the following formula can be applied:
Example:
First Prod. Qty = 174 ml
TMax. first P. Qty = 400 ml @ 35°C
First Prod. Freq. = 5 h
First Prod. Hour = N.A.
The system activates P1 pump every 5 hours. If the temperature reached during the latest dosing is 28°C, then the
pump will dose:
4.4
S
H (
ETTING THE P
The following parameters must be programmed for pH pump operation:
Enter the installer menu, select option Set Point/Timer , press key Enter and then key F more than once, until Set
Point pH is displayed:
ADSP7000570
H)
PUMP P
Set Point pH – Work Mode pH – Prop. Band pH
Set Point pH
The setpoint indicates the value of pH that is intended to keep.
Press keys ▼▲ to set the desired setpoint and Enter to confirm.
Setpoint values that can be set are 5.0÷9.0 pH.
Work mode pH
The operation mode sets the type of solution it is being dosed: Acid (the pump
starts dosing when the value read by the probe is higher than the Setpoint) or
Alkaline (the pump starts dosing when the value read by the probe is lower than
the Setpoint).
Press keys ▼▲ to select the two options and Enter to confirm.
pH Work mode that can be set is Acid/pH
Proportional band pH
Represents the value of the band for the proportional dosing in time.
The pump can be active for maximum 300 seconds. If it is activated for less
time, it must be inactive for a time equal to the difference between the set pH
cycle period (refer to par. 5.1) and the activation time.
Press keys ▼▲ to set the desired value and Enter to confirm.
The proportional band can be selected among the following values:
0.5 – 1 – 1.5 – 3 pH.
rev. 1.6
-
or Alkaline/pH