74
Fault
The burner does not burn
evenly.
The burner goes out after
igniting.
faults
Table (continuation)
Cause
- Burner parts incorrectly
installed.
- Burner parts dirty or damp.
- Wrong type of gas used
(where bottled gas is used).
- Control knob not kept
pressed in long enough
(appliance fitted with
thermocouple).
Solution
- Assemble the burner parts
using the centring ridges and
ensure that they fit properly
together.
- Clean and dry the burner
parts, checking that the
outflow holes are open.
- Check that the gas used is
suitable for the appliance.
- Keep the control knob
pressed in for at least
5 seconds.