INTRODUCTION
Wire Specifications
INTRODUCTION
Use this chart to pull wires in preparation of your installation. Check the national and local building codes BEFORE installation.
DESCRIPTION OF WIRE RUN
Recommended OSDP Reader (Up to 8 units daisy
chained)
INTRODUCTION
Power Wire, 24V DC power supply
INTRODUCTION
Local Area Network (LAN)
CAT 5e or better Network Cable (also for PoE setup)
Grounding the Chassis (use grounding lug in
CAPXLV2)
Door Strike
INTRODUCTION
Magnetic Lock
Dry Contact Closure (Most Gate Operators)
Exit Request (REX)
Supervised Input
Wiegand/Proximity Readers
Postal Lock Box
NOTE: Main power supply and control wiring MUST be run in separate conduits. Conduits must be UL approved for low and high
voltage. Refer to the NEC for additional wiring requirements.
* POSTAL LOCK BOX POSTAL NOTES:
• The postal lock cable length shall not exceed 98.5 ft (30 m) for UL 294 compliance.
Category 5e cabling is the minimum performance category recommended.
Wiring shall be in accordance with the National Electrical Code (ANSI/NFPA 70), local codes and authorities having jurisdiction.
Always provide power from a dedicated source. Plug provided transformer into an outlet wired to its own 10 Amp minimum circuit
breaker. This will prevent two problems:
• Other equipment cannot introduce spikes, noise, surges or dips into the power circuit that will affect the system.
• The system's operation will not be affected if any other equipment develops a short circuit across the power line.
* CAT 5e/6 NETWORK CABLE NOTES:
• For outdoor distances exceeding 140 feet (42.7 m), a UL497 compliant primary surge protector MUST be installed at
the CAPXLV2.
• Distances exceeding 328 feet (100 m) may be accommodated with additional hardware (available through third-party sources).
ACCOUNT SETUP
ACCOUNT SETUP
ACCOUNT SETUP
ACCOUNT SETUP
ACCOUNT SETUP
POWER
NETWORK/MOUNTING
POWER
NETWORK/MOUNTING
WIRE SPECIFICATION
22AWG. 2 twisted pairs (4 Conductor)
(one pair for PWR/GND)
(one pair for D0/D1)
POWER
NETWORK/MOUNTING
Shielded cable is optional terminated
with 100 Ohms at each end.
2-Conductor 14 AWG
2-Conductor 16 AWG
2-Conductor 18 AWG
POWER
NETWORK/MOUNTING
8-Conductor, 24 AWG Twisted pair
12 AWG Copper
2-Conductor 18-22 AWG Shielded
POWER
NETWORK/MOUNTING
2-Conductor 18-22 AWG
2-Conductor 18-24 AWG Shielded
2-Conductor 18-24 AWG
2-Conductor 18-24 AWG
7-Conductor 18-22 AWG Shielded
2-Conductor 18-24 AWG
9
ACCESS CONTROL
ACCESS CONTROL
MAXIMUM RUN DISTANCE
1000 feet (304.8 m)
ACCESS CONTROL
Up to 300 feet (91.4 m)
Up to 200 feet (60.9 m)
Up to 100 feet (30.4 m)
ACCESS CONTROL
328 feet* (100 m)
12 feet (3.7 m)
100 - 250 feet (30.5 - 76.2 m)
ACCESS CONTROL
50 - 125 feet (15.2 - 38.1 m)
500 - 2500 feet (152.4 - 762 m)
500 feet (152.4 m)
500 feet (152.4 m)
500 feet (152.4 m)
250 - 1000 feet (76.2 - 304.8 m)