INTRODUCTION
Gate Access (Wired)
Disconnect power BEFORE making electrical connections. Below is an example of a wiring setup for gate access. Gate access can
be wired to Relay 1, 2, 3, or 4 on the Door of Control Board. LiftMaster
communicate wirelessly instead of using a wired connection (refer to the following page). Input and output port functions on CAPXLV2
can be configured via the myQ Community web portal. Below is an example use case of connections to various external devices.
RFID ANTENNA
with Wiegand output
Power for RFID ANTENNA
(Not Provided)
NOTE: For the LiftMaster RFID reader,
DO NOT use the power
follow the wiring diagram in the manual
supply for the controller
for the LMSC1000.
STATUS
(Not applicable for wireless gate operator connections.)
GATE OPERATOR
(connect to Aux Closed Limit switch -
refer to gate operator manual)
PRIMARY RELAY
GATE OPERATOR
LiftMaster
®
Security+ 2.0
®
gate
operators can be programmed
to communicate wirelessly
instead of using a wired
connection. Refer to the
following page.
*AUXILIARY RELAY
MAGLOCK
Use 18-22 AWG
For DC Power:
Install a 1N4005
diode or equivalent
ACCOUNT SETUP
WIEGAND
KEYPAD
OR
EOL (End of Line)
Resistor (1k ohm)
EXIT
COMMON
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) (provided)
or equivalent
NORMALLY CLOSED
COMMON
+
Power for Maglock
(Not Provided)
DO NOT use the power
supply for the controller
POWER
NETWORK/MOUNTING
Security+ 2.0
®
READER
OR
NOTE: For KPR2000
keypad, wire the pink and
black (ground) wires together.
REQUEST TO EXIT
EXTERNAL FREE EXIT
PUSH
LOOP DETECTOR
BUTTON
OR
NORMALLY CLOSED
AUXILIARY RELAY
Low
Voltage
Power
Supply
Isolation
Relay
NOTE: DO NOT
run high voltage
power within
the CAPXL
enclosure.
ALARM BYPASS
COMMUN
NORMALLY OPEN
17
gate operators can also be programmed to
®
NOTE: The length of the unshielded
wires should be kept to a minimum to
avoid electrical noise.
NOTE: When wiring
a LiftMaster Smart
Reader, follow the
wiring diagram
colors in the
Smart Reader
install guide.
Do not use the
color guide here.
REQUEST TO EXIT
COMMON
STATUS
NORMALLY OPEN
COMMON
NORMALLY OPEN
COMMON
LIGHT
LOAD
LINE
OR
* NOTE: MAGLOCK and ALARM
BYPASS not evaluated by UL.
ACCESS CONTROL