INTRODUCTION
ACCOUNT SETUP
POWER
NETWORK/MOUNTING
ACCESS CONTROL
Postal Lock
1. Remove the wing nut and plug. Discard the wing nut and plug.
2. Remove 4 mounting nuts from studs.
3. Install postal lock using 4 nuts from step 2.
4. Cut the factory installed wire tie from the postal lock switch.
5. Configure postal lock to an access point in the configuration settings for this device on the myQ Community web portal.
The postal lock may be connected to Monitored Input 2 by default.
6. Test the postal lock to ensure proper mapping of the access point to the postal lock.
The postal lock switch is wired from the factory.
NOTE: The postal lock cable length shall not exceed 98.5 ft (30 m). Configuration through the myQ Community web portal is
required.
Postal Lock