INTRODUCTION
OSDP Card Reader
The CAPXLV2 is designed to connect a single or multiple OSDP
readers. The OSDP reader should be installed by following the
following steps:
1. Disconnect power from the CAPXLV2.
2. Prepare RS-485 cables before the connection by adding the
matching resistors (100 ohms) to both ends of the cable.
3. Connect one end of the RS-485 cables and 12VDC power to
the OSDP connector on the CAPXLV2 main board.
4. Turn on power of CAPXLV2 and make sure it is in Admin
mode.
5. Go to OSDP Tab in Admin Mode.
6. Toggle Enable Install New Reader.
7. Make sure the new OSDP reader has default address 0
by following the manufacturer's recommendation. If not,
connect the OSDP reader to 12V power line and GND, within
60 seconds of the reader power cycle, tapping the reader
with configuration card (5044-FEA-OSDP-018) to set to
manufacture default and then disconnect 12V power line.
8. Connect the new OSDP reader to RS-485 cables.
9. The CAPXLV2 should discover the connected reader and
create the reader in myQB. The reader should turn its LED to
amber. The OSDP reader is now installed.
10. To install more OSDP readers, follow steps 7 through 9 for
each new OSDP reader.
The uninstallation or deletion of the OSDP should follow the
following steps:
1. Make sure the OSDP reader to be deleted is connected to RS-485.
Never disconnect OSDP reader before uninstalling or deleting
from Admin UI.
2. Go to OSDP Tab in Admin mode.
3. Select the OSDP reader to be deleted from the Connected
Readers.
4. Click Delete Button.
5. Click Delete in the confirmation Dialog Box.
6. Check if the deleted reader is not displayed under Connected
Readers.
7. Disconnect the deleted reader from RS485 cable and 12V
power line.
ACCOUNT SETUP
POWER
NETWORK/MOUNTING
CAPXLV2 can only install one OSDP reader at a time. You must
complete steps 7 through 9 for an OSDP reader before you
connect another new OSDP reader to the 12 V power.