NOTICE
If anodes are not properly maintained,
underwater aluminum surfaces (such as
the lower unit) will suffer galvanic corro-
sion damage.
• Periodically inspect anodes to make
sure they have not become detached.
• Do not paint anodes, as this will render
them ineffective.
• Periodically clean anodes with a wire
brush to remove any coating which
might decrease their protective ability.
NOTE:
Consult your authorized Suzuki Marine Dealer
for inspection and replacement of internal
anodes attached to the powerhead.
BONDING WIRES
Bonding wires are used to electrically connect
the engine components so they exist in a com-
mon ground circuit. This allows them to be pro-
tected against electrolysis by the anodes.
These wires and their terminals should be
checked periodically to be sure they have not
been damaged.
BATTERY
If you are using a maintenance-free battery,
inspect the window area according to the
instructions on the battery to make sure the bat-
tery is in good condition.
If you are not using a maintenance-free battery,
the battery fluid level should be checked every
100 hours of operation or 12 months. The bat-
tery solution level must be kept between the
MAX and the MIN level lines at all times. If the
level drops below the MIN level line, add DIS-
TILLED WATER ONLY until the battery solution
level reaches the MAX level line.
 WARNING
Battery acid is poisonous and corrosive,
and can cause severe injury.
Avoid contact with eyes, skin, clothing,
and painted surfaces. If battery acid
comes in contact with any of these, flush
immediately with large amounts of water.
If acid contacts the eyes or skin, get
immediate medical attention.