V1,1
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does not
function properly or parts are missing. If unable to do so, have a
qualified technician service the tool.
PROBLEM(S)
Magnetic and motor
do not function
Magnetic functions;
motor does not
Magnetic does not
function; motor does
Hole cutters break
quickly; holes are
bigger than the cutter
Motor running roughly
and/or seizing up
Visit www.princessauto.com for more information
Magnetic Drilling and Tapping Press
POSSIBLE CAUSE(S)
The magnet switch is not connected to the
power supply
Damaged or defective wiring
Defective fuse
Defective magnet switch
Defective control unit
Defective power supply
Damaged or defective wiring
Carbon brushes are stuck or worn out
Defective magnet switch
Defective on/off switch
Defective control unit
Defective armature and/or field
Defective protective reed switch
Defective magnet
Defective fuse
Defective control unit
Play in the guide
Bent spindle
Shaft extending from the motor is bent
Pilot bent
Bent spindle
Shaft extending from the motor is bent
Triangular guide not mounted straight