The control board on the top side of the SC-530/570 allows you to assign the DMX fixture address, which is defined
as the first channel from which the SC-530/570 will respond to the controller.
If you set, for example, the address to channel 5, the SC-530/570 will use the channel 5 to 12 for control.
Please, be sure that you don't have any overlapping channels in order to control each SC-530/570 correctly and
independently from any other fixture on the DMX data link.
If two, three or more SC-530/570 are addressed similarly, they will work similarly.
For address setting follow this procedure :
1. Switch On the SC-530/570 and wait until the fixture reset has finished ("rSt" is flashing at the display).
2. Press the [Mode] key in order to access the main menu. Browse through the menu by pressing the [Up]
and [Down] keys until the display shows "A001". Confirm by pressing [Enter] key and the letter "A" will
flash.
3. Use the [Up] and [Down] keys to select the desired address.
4. Confirm by pressing [Enter] or [Mode] to cancel.
Controlling:
After having addressed all SC-530/570 , you may now start operating these via your lighting controller.
Note:
After switching On, the SC-530/570 will automatically detect whether DMX 512 data's are received. If there are
not received these data's at the DMX input, the display will start to flash "A001" with actually set address.
This situation can be occurred if:
there is not connected the 3 PIN XLR plug (cable with DMX signal from controller) in the input of the SC-530/570
the controller is switch Off or is failed
the cable or connector is failed or the signal wires are swap in the input connector.
Note:
It's necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to ensure
proper transmission on the DMX data link.
6.1 Lamp
The SC-530 is run with a 24V/250W halogene lamp and the SC-570 with a 200W or 250W discharge lamp.
A relay inside of the SC-530/570 allows you to switch On and Off the lamp via itself control board on the top side
or via your controller without affecting the rest of the lighting.
6.2 Switching On and Off the lamp by control board
1. Switch On the SC-530/570 and wait until the fixture reset has finished.
2. Press the [Mode] key in order to access the main menu. Browse through the menu by pressing the [Up] and
[Down] keys until the display shows "LAMP". Confirm by pressing [Enter] key.
3. Use the [Up] and [Down] keys to select "On" for switch On the lamp and "Off" for switch Off the lamp and
press [Enter] to confirm or [Mode] to cancel.
Note :
If you switch On the lamp by control board, then switch Off the SC-530/570 and again switch On the whole unit,
the lamp will automatically Switch On.
If you switch Off the lamp by control board, then switch Off the SC-530/570 and again switch On the whole unit,
the lamp will not shine. (you have to use for Switch On the control board again or external controller).
SC-570:
It is also important to note, that both discharge lamps are cold restrike types, that means, that they have to be
cold before re-striking. For this reason, you have to wait 5 minutes (max. speed of fan must be adjusted) after
having switched Off the lamp before you can switch it back On again. If you try to switch On the lamp within 5
minutes after having switched it Off, the SC-570 will store this information and automatically ignite the lamp
when the 5 minutes period has expired. The message "HEAt" will appear on the control board display at the
back side of the SC-570. If the ignition of the lamp is seven times unsuccessful, on the display will appear
"LA.Er", meaning that the lamp could be damaged or even missed, or there could be a failure on the ignitor or
ballast.
SC-530:
The halogen lamp 24V/250W used in this fixture is possible to switch On and Off and again On etc. without an