Télécharger Imprimer la page

VALBERG 14S40 B XAD929C Consignes D'utilisation page 13

Masquer les pouces Voir aussi pour 14S40 B XAD929C:

Publicité

Les langues disponibles

Les langues disponibles

B
Installation instructions
CAUTION
Risk of electric shock!
Disconnect the power supply before installing the dishwasher.
Failure to do so could result in death or electric shock.
WARNING
For your personal safety:
• Do not use an extension cord or adapter with this appliance.
• Under no circumstances should you cut or remove the
earthed connection from the power cord.
INFORMATION ON ELECTRICAL CONNECTIONS
Please observe the technical characteristics of the appliance in the data sheet attached
to the instructions (voltage, frequency, power, required water pressure, etc.) for your
installation.
A 20A circuit breaker or a 16A fuse on the appliance's dedicated circuit must be used.
The cross-section of the supply cables must be 2.5 mm² and the differential switch,
30 mA.
The outlet must be equipped with a protective ground plug. If the plug is unsuitable or
damaged, replace it and check the electrical installation to ensure that it meets the
above requirements.
Using the appliance
11
EN

Publicité

loading

Ce manuel est également adapté pour:

983801